G Safe connection to the

G Safe connection to the grid VMD460 – Interface Protection System (decoupling protection) compliant with the standards for photovoltaic systems, CHPs, wind and hydroelectric power The VMD460 provides external interface protection system that isolates the connection between the public grid and the power generation system by operating interface switches in case of limit infringements. If voltage and frequency measurements on the power generation system are outside the thresholds required in the standards, the power generation system is isolated from the public grid. The VMD460 is multifunctional and can be used in many applications based on national or plant-specific requirements. The related parameters are saved in pre-set basic programs. The VMD460 combines safe function with a high degree of flexibility and straightforward configuration. Device features ■■ Straightforward commissioning ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ ■■ Pre-set response values for national standards and regulations Single fault safety Monitoring of the interface switches connected Islanding detection df/dt (ROCOF) Vector shift RS-485 interface (data exchange and software update via BMS bus) Test function for the determination of the shutdown time History memory of last 300 events and faults with real-time clock-calendar time stamp Continuous monitoring of phase voltage and line conductor voltage Separate switching conditions after a threshold infringement Test button for the tripping circuit Language selection (German, English, Italian) Illuminated, multi-line graphic display Password protection for device settings Automatic disconnection device between a power generation system and the public grid Interface protection system VMD460 Example applications Photovoltaicsystem Selection of devices & Project scheduling & Commissioning VMD460 Schematic diagram of continuous voltage and frequency monitoring Application as per – CEI 0-21 – VDE-AR-N 4105 – C10/11 – G59/2 Supply to the public grid – G59/3 – G83/2 – DIN V VDE V 0126-1-1/A1 – BDEW regulations oncept 10

G Support at all stages All-round service for your installation: Remote, by phone, on-site Planning & Concept Competent service for maximum safety and high availability of your installation Expansion & Modernisation Selection of devices & Project scheduling Installation Operation & Maintenance Installation & Commissioning Operation & Maintenance From planning to modernisation – Our know-how and our expertise is at your disposal in all project phases. Furthermore, our first-class service ensures you the maximum safety for your electrical installations. The service we offer range from telephone support through repairs to on-site service – with state-of-the-art measuring devices and professional employees. Many service activities, fault clearance, but also analysis and inspections, can be carried out by remote maintenance – no technician needs to be on-site, saving you time and money. Convincing benefits: ■■ High availability of your installation by responding faster to fault messages ■■ Automatic control, analysis, correction, readjustments/updates are possible ■■ Competent assistance on changing settings and with updates ■■ Regular checking of your installations/power quality/monitoring devices ■■ Significant cost reduction by reduced downtimes and shorter service times 11 Ex

pv Europe RSS Feed